Customization: | Available |
---|---|
Warranty: | 1year |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PDLC ODC ODVA Fiber Optic Armoured Cable Remote Radio Head cell Tower 7.0mm BBU RRU Non-metal
The mobile pre-terminated armoured cable reel is developed for temporary field deployment where fiber connections are required. It comes in a portable cable reel for ease of transportation and deployment. The armoured cable is flexible and is able to withstand multiple usages without kinks. One end of the cable is fixed to the reel while the other end is coiled freely for patching to the equipments. Generally these will be customized base on user's requirement so there are options of various cable and connector type with any cable length which then will determine the size of the reel.
Because the BBU RRU mode is generally used in short-distance and indoor coverage scenarios, the optical cable must pass through corridors, indoor wiring ducts, shafts, etc., and air blowing may be used in some places, so this type is different from ordinary optical cables and belongs to special In the category of light, the cable generally requires light weight, small outer diameter, small bending radius, dry structure, flame retardant and tensile strength. We generally refer to this type of fiber optic cable as a cable, consisting of a single-core soft cable, aramid armor and a low-smoke halogen-free jacket.
Application:
Multi-purpose Outdoor
For connection between distribution box and RRH
Fiber-to-the-Antenna (FTTA)
Deployment in Remote Radio Head cell tower applications
Latest and next-generation mobile communication systems(GSM, UMTS, CMDA2000, TD-SCDMA, WiMAX, LTE,etc.) deploy fiber-optic feeders to link the base station with the remote unit at the antenna mast.
Automation and industrial cabling
ODVA provides highest reliability and operating safety. The ruggedized design provides highest mechanical and thermal robustness which keeps the data lines alive even in case of
shock, strongest vibration, or accidental misuse.
Surveillance systems
Security camera manufacturers chooseODVA connectors for its compact size and robust design. ODVA assemblies are easy to install even in areas difficult to access and provide highest installation safety.
Naval and ship building
The high corrosion resistance convinced both naval and civil ship builders to use ODVA assemblies for on-board communication systems. The nickel plated connectors withstand humid and salty environments and guarantee life times of 20 years and beyond.
Broadcast
Qffers a range of mobile cabling systems and ODVA assemblies for temporary cable installations
required for the broadcasting of sport events, car racing, etc.and for temporary connections in case of natural hazards.
Optical performance :
Items | Single mode | Multimode | ||||||
PC | UPC | APC | 62.5/125 | 50/125 | 50/125 10G | |||
Insertion Loss | <0.3dB | <0.3dB | ||||||
Return Loss | ≥45dB | ≥50dB | ≥60dB | ≥35dB | ||||
Durability | <0.1dB typical change, 500 matings |
|||||||
Operating Temperature | -40 to +75 | -40 to +75 | ||||||
Ferrule Hole Sizes | 125.0+1/-0um, Conentricity:≤1um | 125um,Conectricity:1≤3um | ||||||
125.3+1/-0um, Conentricity:≤1um | 127um,Conectricity:1≤3um | |||||||
125.5+1/-0um, Conentricity:≤1um |
128um,Conectricity:1≤3um |
Each fiber can be identifiable throughout the length of the cable in accordance with the following color sequence. Fiber color in each tube starts from No. 1 Blue.
Fiber Colors
No | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Slate | White | Red | Black | Yellow | Purple | Pink | Aqua |
No | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Slate | White | Red | Natual | Yellow | Purple | Pink | Aqua |
<color> with evenly spaced black ring marks.
The color of the tube will be natural.
The finished cables can be subjected to the following mechanical, electrical and environmental conditions.
Item | Test Method | Requirements |
Tensile performance |
IEC 60794-1-21-E1 Load: 0.5G Cable length under tension: Not less than 50m. Duration of load sustain: 1min. Velocity of transfer device: 10mm/min |
The maximum increase in attenuation less than 0.1 dB . The maximum fiber strain less than 0.6% under maximum tensile short term load. No change in attenuation after test at 1550nm. Under visual examination without magnification, no damage to the sheath or to the cable elements after test. |
Crush |
IEC 60794-1-21-E3 Load: 200N Duration of load: 1min |
No change in attenuation after test at 1550nm. Under visual examination without magnification, no damage to the sheath or to the cable elements. The imprint of the striking surface on the sheath is not considered mechanical damage. |
Bend |
IEC 60794-1-21-E11A Mandrel radius: 10 times cable diameter Turns:4 Cycles:3 |
No change in attenuation at 1550nm after test. Under visual examination without magnification, no damage to the sheath or to the cable elements. |
Repeated bending |
IEC 60794-1-21-E6 Bending radius: 20 times cable diameter Cycles: 25 Load: 25N Duration of cycle: Approximately 2s. |
No change in attenuation at 1550nm after test. Under visual examination without magnification, no damage to the sheath or to the cable elements. |
Torsion |
IEC 60794-1-21-E7 Cycles:5 Length under test: 1m Turns: ±180° Load: 0.5G |
The variation on attenuation for each fiber less than 0.1dB at 1550nm Under visual examination without magnification, no damage to the sheath or to the cable elements. No permanent change in attenuation after test |
Temperature cycling |
IEC 60794-1-22-F1 Sample length: at least 1000m Temperature range: -20ºC~+70ºC Cycles: 2 Temperature cycling test dwell time: 12 hours |
No change in attenuation coefficient at 1550nm after test. |
Water Penetration |
IEC 60794-1-22-F5B Time : 24 hours Sample length : 3m Water height : 1m |
No water leakage |
Compound flow |
IEC 60794-1-21-E14 Sample count:5 Sample length:300 ±5 mm, Remove length: 130 ±2,5 mm, Time:24h |
No filling compound dripped. |
Jetting Performance | Conform to IEC 60794-5-10 | |
Other parameters | Conform to IEC 60794 |
Remark: "No attenuation changes" is considered as the attenuation changes ≤ 0.05 dB.
Standard delivery lengths are 2km, 4km, 6km with a tolerance of -1%~+3%
Fiber Count | Drum length (m) | Drum Size Φ×W (mm) | Packing Size L×W×H (mm) | Weight (Gross) (kg) |
2~12 Fibers φ 2.0-2.5 | 2000 | Φ450×370 | 480×370×645 | 27 |
4000 | Φ500×370 | 530×370×695 | 39 | |
6000 | Φ550×370 | 580×370×745 | 51 | |
14~24 Fibers φ 2.8 | 2000 | Φ500×370 | 530×370×695 | 31 |
4000 | Φ550×370 | 580×370×745 | 46 |
Packing
Wooden or plywood drums with protection.
Are you a trading company or manufacturer?
We are professional supplier. We are not only a trading company but also a manufacturer. Our factory name is Comelink co.,LTD
What are your main products?
Our products cover mainstream brands of OLT and PON cards, ONT ONUs, enterprise switches, optical modules and OEM ODN equipment.
Do ONT ONU products provide customized services?
Yes, we can customize your logo, company information, pre-configuration, packaging box, etc.
What is your delivery time?
Usually we can ship within 1-3 days for small quantity, and about 15-20 days for large quantity.
What are your payment terms?
Alipay, T/T, Western Union and Paypal. This is negotiable.
What is the shipping method?
Shipping by sea, air or express (EMS, UPS, DHL, TNT, FEDEX, etc.).
For OLT, how to ensure quality?
We conduct strict testing before shipment to ensure the goods are available, and electronic reports will also be shared with you. In addition, we also provide one-year warranty and technical service.
How do you make our business a long-term and great relationship?
We maintain good quality and competitive prices to ensure our customers benefit;
We respect every customer as our friend, and we sincerely do business and make friends with them, no matter where they come from.
Is there a minimum order quantity?
No, a test sample is also available.