Customization: | Available |
---|---|
Application: | Communication, Aerial Duct Direct Buried |
Type: | Outdoor Fiber Cable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Structure
|
|
Unit
|
Parameter
|
|
Fiber count
|
|
fibers
|
6~24
|
|
Loose tube Diameter
|
|
mm
|
Ф1.8~2.0
|
|
Cores of per tube
(no more than) |
|
--
|
6
|
|
Central strength member diameter(FRP)
|
|
mm
|
2.0
|
|
Element
|
|
--
|
5
|
|
FRP
|
|
|
1.6*19
|
|
Cable diameter
|
|
mm
|
15.7±0.5
|
|
Weight
|
|
Kg/km
|
249
|
|
wooden drum 2km
|
|
mm
|
1300*760*500(D*d*L)
|
|
Tensile strength
|
Long term
|
N
|
4500
|
|
|
Short term
|
N
|
8800
|
|
Crush Resistance
|
Long term
|
N
|
2200
|
|
|
Short term
|
N
|
3000
|
|
Bending Radius
|
Dynamic
|
mm
|
≥25*OD
|
|
|
Static
|
mm
|
≥12.5*OD
|
|
Operating Temperature
|
|
|
-40 --- +60
|
No
|
Item
|
Test standard
|
Method
|
Details specification
|
1
|
Tensile
test |
IEC-60794-1-E1
|
-Max. Tensile strength:5000N
-Sample length:50 meters -Time: 1minutes |
-Fiber strain at maximum
Load: max. 0.33% -Attenuation increase<0.10dB, -Reversible |
2
|
Crush
test |
IEC-60794-1-E3
|
-Load: 3000N/100mm
-Time: 1 minutes -Number of tests: 3 |
-No splits or cracks in the
outer jacket; -Attenuation increase<0.10dB, -Reversible |
3
|
Impact
test |
IEC-60794-1-E4
|
-Impact energy:1kg
- Height:1 meter -Impact points: 5 --Number of impacts: 5 |
-No splits or cracks in the outer jacket
-Attenuation increase≤0.10dB -Reversible |
4
|
Repeated bending
|
IEC-60794-1-E6
|
-1m cable length with 250N weight,
30 cycles |
-No damage to the outer jacket
-Attenuation increase ≤0.10dB -Reversible |
5
|
Torsion
test |
IEC-60794-1-E7
|
-1m cable length with 250N weight
±90 degrees -Time:10 cycles |
-No damage to the outer jacket
-Attenuation increase ≤0.10dB -Reversible |
6
|
Bending
test |
IEC-60794-1-E11
|
-Diameter of mandrel: 25×D
-Number of turns/helix:10 -Number of cycles: 5 |
-No damage to the outer jacket
- No fiber break -Reversible |
7
|
Temperature cycling test
|
IEC-60794-1-F1
|
-Temperature step:
+20→-40→+60→-40→ +60→+20 -Time per each step: 24 hrs -Number of cycles: 2 cycles |
-Attenuation variation for reference value(the attenuation to be measured before test at +20±3) ≤0.05dB/km,
-Reversible |
8
|
Water penetration test
|
IEC-60794-1-F5
|
-Water height: 1m,
-Sample length:3m, -Duration of test: 24hrs |
-No water leakage at the end of the sample
|
9
|
Drip test
|
IEC-60794-1-E14
|
-Five 0.3m samples suspended vertically in a climate chamber, raised temperature to +70
|