Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Application: | Communication |
| Type: | Fiber Optic Cable |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Special composite material loose tube, reducing the retraction of low temperature tube;
2. Precisely control the excess length of the optical fiber, and the performance of the optical cable is stable;
3. Unique process control to prevent sheath wrinkling during air blowing;
4. Outer sheath of high-density polyethylene to increase the air blowing distance.
IEC 60794-5IEC 60794-1-2 or YD/T 1460-2006
The GCYFXY series is designed for air-blowing installation in micro-ducts, featuring high fiber density and low friction HDPE sheaths.
1. Technical Parameters & Models
| Micro Cable Model | MTE 1.8 | MTE 2.0 | MTE 2.3 | MTE 2.5 | MTE 2.8 |
| Fiber Count | 24 | 24 | 6-12 | 2-12 | 14-24 |
| Nominal Outer Diameter | 1.8 mm | 2.0 mm | 2.3 mm | 2.5 mm | 2.8 mm |
| Approximate Weight | 2.6 kg/km | 4.0 kg/km | 5.0 kg/km | 6.0 kg/km | 7.0 kg/km |
| Maximum Pull (Tensile) | 40 N | 40 N | 50 N | 60 N | 60 N |
| HDPE Sheath Thickness | Nominal: 0.20 mm | Minimum: 0.15 mm | ||||
| Max Crushing Force | 600 N / 100 mm | ||||
| Temperature Range | Storage: -30 to +60°C | Installation: -10 to +40°C | Operation: -20 to +50°C | ||||
| Cable Life | Estimated 25 years | ||||
| Fiber Type | Parameter | G.652 (SM) | G.655 (SM) | 50/125μm (MM) | 62.5/125μm (MM) |
| Attenuation | @850nm | -- | -- | ≤ 3.0 dB/km | ≤ 3.0 dB/km |
| (+20°C) | @1300/1310nm | ≤ 0.36 dB/km | -- | ≤ 1.0 dB/km | ≤ 1.0 dB/km |
| @1550nm | ≤ 0.22 dB/km | ≤ 0.23 dB/km | -- | ||
| Bandwidth | @850nm | -- | -- | ≥ 500 MHz·km | ≥ 200 MHz·km |
| (Class A) | @1300nm | -- | -- | ≥ 1000 MHz·km | ≥ 600 MHz·km |
| NA | Numerical Aperture | -- | -- | 0.200±0.015 | 0.275±0.015 |
| Cut-off λ | Cable Cut-off | ≤ 1260 nm | ≤ 1480 nm | -- | -- |
| Fiber Type | Parameter | G.652 (SM) | G.655 (SM) | 50/125μm (MM) | 62.5/125μm (MM) |
| Fiber Count | Microtube Size | Typical Delivery Length |
| 2-12 Cores | 3.5 / 5.0 mm | 800 - 1500 meters |
| 14-24 Cores | 5.5 / 7.0 mm | 500 - 1500 meters |
| Test Item | Reference Standard | Test Conditions | Performance Requirements |
| Stretch (Tensile) |
IEC 60794-1-2-E1 GB/T 7424.2-E1 |
Short-term: Maximum pull Long-term: 1/3 Maximum pull |
Fiber Strain: Short-term ≤ 0.3%, Long-term ≤ 0.1% Attenuation: Short-term ≤ 0.1 dB; Long-term: none apparent. No obvious strain after stress removal. |
| Flattening Force (Crush) |
IEC 60794-1-2-E3 GB/T 7424.2-E3 |
Short-term: 600N Long-term: 200N |
Attenuation: Short-term ≤ 0.05 dB; Long-term: no obvious attenuation. Surface: No visible cracks on sheath; no obvious residual attenuation after stress removal. |
| Repeated Bending | IEC 60794-1-2-E6 GB/T 7424.2-E6 |
Radius: 20 × Cable Diameter Bends: 25 cycles |
No obvious residual attenuation. No visible cracks in the sheath. |
| Torsion Test | IEC 60794-1-2-E7 GB/T 7424.2-E7 |
Load: 15N Angle: ±180° Twists: 5 |
Fiber does not break; sheath has no visible cracks. No obvious residual additional attenuation after stress relief. |
| Winding Test | IEC 60794-1-2-E11A GB/T 7424.2-E11A |
Load: 15N Mandrel: 20 × Cable Diameter Turns: 10 (5 cycles) |
Fiber does not break. Sheath has no visible cracks. |
| Winding Test | IEC 60794-1-2-E11A GB/T 7424.2-E11A |
Load: 15N Mandrel: 20 × Cable Diameter Turns: 10 (5 cycles) |
Fiber does not break. Sheath has no visible cracks. |
| Test Item | Testing Method | Required Performance Indicators |
| Temperature Performance | IEC 60794-1-2-F1 | Fiber additional attenuation (1550nm) ≤ 0.1 dB/km |
| Water Permeability | IEC 60794-1-2-F5B | Conditions: 1m water height, 3m cable, 24 hours test time. Result: No water leakage from the other end of the micro-cable. |
| Trickle Performance(Drip Test) | IEC 60794-1-2-E14 | Conditions: Maintained at 70°C for 24 hours. Result: Microcable No Fill Compound Drip Out. |