Customization: | Available |
---|---|
Application: | Communication |
Type: | Fiber Optic Cable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
|
G.652
|
G.655
|
50/125μm
|
62.5/125μm
|
|
Attenuation(+20)
|
@850nm
|
|
|
≤3.0dB/km
|
≤3.0dB/km
|
|
|
@1300nm
|
|
|
≤1.0dB/km
|
≤1.0dB/km
|
|
|
@1310nm
|
≤0.36dB/km
|
≤0.36dB/km
|
|
|
|
|
@1550nm
|
≤0.22dB/km
|
≤0.23dB/km
|
|
|
|
|
@850
|
|
|
≥500MHZ·km
|
≥200MHZ·km
|
|
|
@1300
|
|
|
≥1000MHZ·km
|
≥600MHZ·km
|
|
Numerical aperture
|
|
|
|
0.200±0.015NA
|
0.275±0.015NA
|
|
Optical cable cut-off wavelength
|
|
≤1260nm
|
≤1480nm
|
|
|
Micro cable model
|
GCYFXYxxFMTE +outer diameter
|
|
|
|
|
||||
|
MTE1.8
|
MTE2.0
|
MTE2.3
|
MTE2.5
|
MTE2.8
|
||||
Fiber count
|
24
|
24
|
612
|
212
|
1424
|
||||
HDPE Outer Sheath Thickness
|
Nominal0.20mmLeast 0.15mm
|
|
|
|
|
||||
Nominal outer diameter
|
1.8mm
|
2.0mm
|
2.3mm
|
2.5mm
|
2.8mm
|
||||
Approximate weight
|
2.6 kg/km
|
4.0 kg/km
|
5.0 kg/km
|
6.0 kg/km
|
7.0kg/km
|
||||
Cable Attenuation (Single Mode Fiber)
|
1310nm/1550nm≤0.35/0.22dB/km
|
|
|
|
|
||||
Maximum pull
|
40N
|
40N
|
50N
|
60N
|
60N
|
||||
Maximum crushing force
|
600N/100mm
|
|
|
|
|
||||
Allowable minimum bending radius
|
10 times/20 times the outer diameter of the optical cable
|
|
|
|
|
||||
Applicable temperature range
|
Storage -3060; Installation -1040; Operation -2050
|
|
|
|
|
||||
Cable life (estimated)
|
25 years
|
|
|
|
|
Test Equipment
|
Pipeline models suitable for air delivery and corresponding typical air delivery lengths
|
|
|
||
Polyment: PRM-196 , PR140 etc. Air pressure: 13bar
|
Fiber count
|
Microtubule model
3.5/5.0mm |
Microtubule model
5.5/7.0mm |
||
|
212 cores
|
800m
|
1500m
|
||
|
1424 cores
|
500m
|
1500m
|
Item
|
Test reference standard
|
|
Test Results
|
|
Remark
|
|||||
Stretch
|
IEC 60794-1-2-E1
GB/T 7424.2-E1 |
|
Fiber strain%
|
Attachment attenuationdB
|
The short-term test pull is the maximum pull, The long-term test pull is 1/3 of the maximum pull
|
|||||
|
|
|
Short term ≤0.3 Long-term ≤0.1
|
Short term: ≤0.1, No obvious strain after stress removal; Long term: none apparent
|
|
|||||
|
|
IEC 60794-1-2-E3
GB/T 7424.2-E3 |
Short-term crushing force: additional attenuation ≤0.05; Long-term crushing force: no obvious; After the stress is removed, the
optical fiber has no obvious residual additional attenuation, No visible cracks on sheath surface |
|
Short-term test pressure: 600N
Long-term test pressure: 200N
|
|||||
|
|
IEC 60794-1-2-E6
GB/T 7424.2-E6 |
After the test: the optical fiber has no obvious residual attachment attenuation; No visible cracks in sheath
|
|
Bending radius = 20 times the microcable diameter
|
|||||
|
|
|
|
|
load=15N
|
|||||
|
|
|
|
|
Number of bends25
|
|||||
|
|
IEC 60794-1-2-E7 GB/T 7424.2-E7 |
After the test: the fiber does not break and the sheath has no visible cracks, After stress relief, there is no obvious residual
additional attenuation |
|
Twist angle±180º
|
|||||
|
|
|
|
|
load=15N
|
|||||
|
|
|
|
|
Number of twists5
|
|||||
|
|
IEC 60794-1-2-E11A
GB/T 7424.2-E11A |
|
|
Mandrel diameter = 20 times microcable diameter
|
|||||
|
|
|
|
|
Number of close turns=10
|
|||||
|
|
|
|
|
Cycles=5
|
|||||
All the above results are tested at 1550nm wavelength
|
|
|
|
|
|
Item
|
Testing Method
|
The indicators that the test should achieve
|
|
IEC 60794-1-2-F1
|
Fiber additional attenuation(1550nm)
|
|
|
≤0.1 dB/km
|
Water Permeability
|
IEC 60794-1-2-F5B
|
1m water height, 3m cable, test time 24 hours No water leakage from the other end of the micro-cable
|
Trickle Performance
|
IEC 60794-1-2-E14
|
The microcable is maintained at an ambient temperature of 70°C for 24 hours Microcable No Fill Compound Drip Out
|