Customization: | Available |
---|---|
Type: | Tool |
Certification: | CE, ISO, RoHS, GS |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optical Fiber Curing Oven Fiber Optic Tools Power 750W Heating tools φ3.0,φ2.0,φ0.9
This equipment employs two sets of independent precise heating control systems to respectively control two heating boards which are able to simultaneously cure 24 ferrules (standard dimension is φ 2.5mm). This equipment features high production efficiency, stable and reliable quality. (Note: D employs one set of precise heating control system and one heating board.) Different types of products can be cured using different heating tools.
Name and function of each part
1. Heating tool
It is a dismountable fixture, which is used to install the ferrule to be cured, and
is inserted into heating board to heat ferrule to be cured.
2. Heating board
It is securely mounted on panel, and internal heating device is used to generate heating and cure ferrule.
3.Fuse
Type of fuse is 2A/220V
4.Temperature controller
It is used to control heating temperature of heating board, and temperature can be adjusted within 60ºC~150ºC (it is prohibited to make temperature over 150ºC, otherwise the equipment will be damaged).
5.Power switch
It is used to turn on or off the power.
6.Timing switch
Press this switch to start up time relay, and press twice continuously this switch to stop timer.
7.Time relay
Adjusting parameters of time relay can shorten or prolong heating and curing time (now relay is working).
8. Heating-on indicator
When this indicator is on, the equipment is in heating status.
9.Heating-off indicator
When this indicator is on, the equipment stops heating
Chapter 3 Operation
3.1 Check before startup
1.Check whether component of equipment is complete
2.Check whether screws and buttons on panel are loose or missing
3.Check whether power line is properly connected
3.2 Setting of heating temperature and time
3.2.1 Setting of heating time
1. Remove the enclosure of temperature controller and time relay on panel
2. Adjust digital parameters to set required temperature and time.
3. Install the enclosure.
3.2.2 Setting of heating temperature
1. Press MODE button, the red number on panel representing temperature
changes into as shown in left, and now change the green number under red
number to set temperature.
Chapter 4 Common failures and causes
The following are some failures occurring to curing oven and remedies. Please duly
contact us for the failures which occur in your equipment and are not shown in the
following.
Common failures and causes:
Failure | Cause | Remedy |
Power indicator is not on after startup |
Power plug is not properly connected No electricity |
Properly connect the plug |
Fuse damaged | Replace fuse | |
Press timing-on button, timer is not on |
Timer is set to zero | Reset timer |
Timer does not work |
Replace with a new timer |
|
Ferrule can not be cured | Set temperature is too low |
Reset temperature controller |
Set time is too short | Prolong curing time | |
Heating board can not generate heating |
Temperature is set to zero |
Adjust temperature controller |
Chapter 5 Annex
5.1 Main parameters of equipment
Voltage 220V±10% 50Hz
Power 750W(D 400W)
Overall dimension 550mm(L)×180mm(H)×350mm(W)
Ambient temperature 10ºC~40ºC
Relative humidity 15~85%
5.2 Optional parts of equipment
Heating tools: φ3.0,φ2.0,φ0.9 ,ST and φ1.25/ 2.0 type; Custom heating tool is
also optional on client's request.