Customization: | Available |
---|---|
Application: | Communication |
Type: | Fiber Optical Cable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item
|
|
Unit
|
Specification
G. 657B3
|
|
Mode field diameter
|
1310nm
|
mm
|
9.2 ± 0.4
|
|
|
1550nm
|
mm
|
10.4 ± 0.5
|
|
Cladding diameter
|
|
mm
|
125.0 ± 0.7
|
|
Cladding non-circularity
|
|
%
|
£1.0
|
|
Core concentricity error
|
|
mm
|
£0.5
|
|
Coating diameter
|
|
mm
|
242 ± 7
|
|
Coating/cladding concentricity error
|
|
mm
|
£12
|
|
Cable cut-off wavelength
|
|
nm
|
£ 1260
|
|
Attenuation Coefficient
|
1310nm
|
dB/km
|
£0.35
|
|
|
1383 nm
|
dB/km
|
≤0.33
|
|
|
1550nm
|
dB/km
|
£0.21
|
|
|
1625 nm
|
dB/km
|
≤0.23
|
|
Proof stress level
|
|
kpsi
|
≥100
|
Item
|
Contents
|
Unit
|
Value
|
|
Optical Fiber
|
/
|
/
|
1
|
|
Tight buffer fiber
|
Diameter
|
mm
|
0.9±0.05
|
|
|
Material
|
/
|
LSZH
|
|
Filler
|
Material
|
/
|
Aramid yarns
|
|
Outer jacket
|
Diameter
|
mm
|
3.0±0.1
|
|
|
Material
|
/
|
TPU
|
|
|
Color
|
/
|
Black
|
|
|
Short term
|
N
|
500
|
|
|
Long term
|
N
|
200
|
|
|
Short term
|
N/100mm
|
500
|
|
|
Long term
|
N/100mm
|
100
|
|
Cable attenuation
|
|
dB/km
|
SM: <= 0.4 at 1310nm, <= 0.3 at 1550nm
|
|
Cable weight (Approx.)
|
|
kg/km
|
8.2
|
Item
|
Test Method
|
Acceptance Condition
|
Tensile Strength
IEC 60794-1-2-E1 |
- Load: Short term tension
- Length of cable: ≥ 50m - Load time: 5min |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
IEC 60794-1-2-E3 |
- Load: Short term crush
- Load time: 1min |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
|
- Load: Long term crush
- Load time: 10min |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
Impact Test
IEC 60794-1-2-E4 |
- Points of impact: 3
- Times of per point: 1 - Impact energy: 1J |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
Repeated Bending
IEC 60794-1-2-E6 |
- Bending radius: 20 x OD
- No. of cycle: 100 - Load: 20N |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
Torsion
IEC 60794-1-2-E7 |
- Length: 1m
- Twist angle: ±180° - No. of cycle: 10 - Load: 20N |
- Loss change £ 0.1dB@1550nm after test.
- No fiber break and no sheath damage. |
Temperature Cycling
IEC 60794-1-2-F1 |
- Temperature: -20~+70
- Time of each step: 8h - Number of cycle: 2 |
- Loss change £ 0.5dB@1550nm.